weberpral E

The reformulated monocouche — a one-coat through-coloured render that is the finished facade in itself, with no paint over it and no maintenance cycle beyond washing. weberpral E replaces part of the cement with an alternative binder, and on the declarations it lands about 7% below the standard weberpral M. Made at Weber’s Telford plant. It is one of the first UK monocouche renders with a Type III environmental label at all, which is more notable than the size of the saving.

Manufacturer page
Saint-Gobain Weber weberpral E

Carbon and evidence

Product Evidence

Evidence currently held for the Saint-Gobain Weber product record.

Saint-Gobain Weber

Recorded Carbon Result

0.158kgCO₂e/kg

A1–A3 Climate Change (total) per kilogramme of render as applied. There is no per-m² figure in this declaration — no coverage rate is stated — so multiply by the spread rate for the coat thickness actually specified. Net of 0.0126 biogenic against 0.169 fossil, the biogenic term coming from timber pallets rather than the render.

Indicator: GWP-total

weberpral E monocouche render (EPD-IES-0017225)

A1–A3 covers raw-material supply, transport to manufacture and manufacturing. It is product-stage information, not a whole-life result.

Environmental Product Declaration

EPD recorded
Coverage
Product family
Declared unit
1 kg
Programme
EPD International (The International EPD® System)
Registration
EPD-IES-0017225
Standard
EN 15804:2012+A2:2019, ISO 14025
Valid until
2029-10-17
Verification
Third-party verified

weberpral E coloured monocouche, manufactured at Weber's Telford plant.

Read the EPDSource: Climate Change (total / fossil / biogenic / land use change) rows of the results table

Carbon profile

kgCO2e per 1 kg · each bar starts at zero · local scale

A1-A3 product

0.158

A4-A5 site*

0.106

B use

0

C end of life

0.0245

D reuse / recycling

0

adds carbon stores or removes EPD scenario* reuse/recycling potential (D)
* EPD transport and installation scenario, not this project's. The declared total is 0.158 while fossil + biogenic + land-use-change sums to 0.15658 — a residual of 0.00142, slightly beyond the accumulated half-ulp of three-significant-figure values. This is NOT a transcription error: the declaration prints the explicit warning "Please note Climate Change Total may not be the sum of Climate Change (fossil), Climate Change (biogenic) and Climate Change (land use change)." The manufacturer is stating up front that the split will not reconcile. The declared Climate Change (total) row is treated as authoritative, per EN 15804 convention. The sibling weberpral M declaration reconciles exactly. Module D shows potential impacts or benefits from reuse, recovery or recycling after the product's assessed life. It is reported separately and never added to A-C. Do not compare bar lengths between materials. Each chart may use a different scale and declared unit.

Reported GWP Modules

Displayed as stored; modules are not added together here.

A1–A3

0.158 kgCO₂e

per 1 kg

A4*

0.0145 kgCO₂e

per 1 kg

A5*

0.0916 kgCO₂e

per 1 kg

B1

0 kgCO₂e

per 1 kg

C1

0.00402 kgCO₂e

per 1 kg

C2

0.00625 kgCO₂e

per 1 kg

C3

0 kgCO₂e

per 1 kg

C4

0.0142 kgCO₂e

per 1 kg

D

0 kgCO₂e

per 1 kg

* A4/A5 are EPD scenarios, not project-specific results. Module D is outside the A–C system boundary and is not added to A–C. Module nomenclature follows BS EN 15978 / EN 15804. Declared values are suitable as inputs to a whole life carbon assessment under the RICS Professional Standard (2nd edition); this panel is not an assessment.

Upfront Carbon (A1–A5)*

0.264 kgCO₂e per 1 kg

A1–A3 0.158 + A4 0.0145 + A5 0.0916 · GWP-total (printed as Climate Change total), as declared

* Includes the EPD’s A4/A5 scenario assumptions, not project-specific transport or installation. This is the aggregation the proposed Part Z applies upfront limits to. The A1–A3 figure includes declared biogenic storage of -0.0126 kgCO₂e; Part Z aggregates upfront carbon excluding sequestered carbon, which is the assessor's adjustment to make.

Sourced Product Claims

  • About 7% below weberpral M on the declarations (0.158 vs 0.170 kgCO2e/kg) — a modest, verified savingThird-party verifiedSource
  • Third-party verified EPD, valid to 2029-10-17Third-party verifiedSource

Evidence Sources

weberpral E monocouche render (EPD-IES-0017225)

EPD International (The International EPD® System)

Third-party verified

Comparison Status

This result should be displayed for information only and not ranked against another product.

  • • The EPD is not linked to an evidence source.

Design & Specification Notes

Qualitative notes for early design discussion. Not product-specific EPD evidence, and not a basis for numerical comparison.

The reformulated monocouche — a one-coat through-coloured render that is the finished facade in itself, with no paint over it and no maintenance cycle beyond washing.

Typical Uses

  • Facade cladding
  • Weather protection
  • External accents

Key Performance

Weather-resistant finish for facade exposure.

Typical Service-Life Estimate

40 years

Generic estimate for early design discussion; confirm with the manufacturer.

Specification Actions

  • Confirm the current EPD covers the selected product, finish and manufacturing route.
  • Calculate transport distances for primary materials.
  • Document material reuse or reclaimed content percentages.

Indicative Health & Indoor Air

low Risk
Evidence:Third-party verified

Specification

Range
weberpral
Finish
Through-coloured monocouche render
Country of manufacture
United Kingdom

Cookies — essential ones keep the site working; optional analytics help us improve it. No advertising cookies.