VELFAC 200
Composite window with a factory-finished aluminium exterior over an engineered timber inner frame — the aluminium takes the weather and colour, the timber gives warmth and insulation inside. Slim sightlines and large glass areas; Plus achieves U-values around 1.5 W/m²K, triple-glazed ENERGY down to 0.8.

Carbon and evidence
Product Evidence
Evidence currently held for the VELFAC product record.
Recorded Carbon Result
A1–A3 GWP-total per m² of window, per EPD (top-guided VELFAC 200)
Indicator: GWP-total
VELFAC 200 Environmental Product Declaration · PDF p. 10, potential environmental impact tableA1–A3 covers raw-material supply, transport to manufacture and manufacturing. It is product-stage information, not a whole-life result.
Environmental Product Declaration
EPD recorded- Coverage
- Representative product
- Declared unit
- 1 m² window
- Programme
- EPD International / EPD Danmark
- Registration
- S-P-07591 (EPD Danmark MD-23079)
- Standard
- EN 15804+A2
- Valid until
- 2028-02-10
- Verification
- Third-party verified
Declaration is for a VELFAC 200 ENERGY top-guided window per m²; confirm opening type and specification.
Carbon profile
kgCO2e per 1 m² window · each bar starts at zero · local scale
A1-A3 product
72.9
A4-A5 site*
—
B use
—
C end of life
21
D reuse / recycling
-23
Reported GWP Modules
Displayed as stored; modules are not added together here.
A1–A3
72.9 kgCO₂e
per 1 m² window
C1
0 kgCO₂e
per 1 m² window
C2
0.602 kgCO₂e
per 1 m² window
C3
19.3 kgCO₂e
per 1 m² window
C4
1.08 kgCO₂e
per 1 m² window
D
-23 kgCO₂e
per 1 m² window
Service Life — the B4 Replacement Input
40 years · basis not recorded
≈2 installations over a 60-year building study period.
Evidence Sources
EPD International / EPD Danmark · PDF p. 10, potential environmental impact table
Coverage: Declaration is for a VELFAC 200 ENERGY top-guided window per m²; confirm opening type and specification.
Comparison Status
The record contains the basic metadata required for a controlled comparison. Products must still perform the same function and use compatible units, PCRs and lifecycle scope.
Design & Specification Notes
Qualitative notes for early design discussion. Not product-specific EPD evidence, and not a basis for numerical comparison.
Composite window with a factory-finished aluminium exterior over an engineered timber inner frame — the aluminium takes the weather and colour, the timber gives warmth and insulation inside.
Typical Uses
- •Glazing systems
- •Daylight openings
- •Thermal envelope
Key Performance
Supports daylight and thermal performance of the envelope.
Specification Actions
- •Verify product-specific recycled content and manufacturing energy route.
- •Use reversible fixings to support high-value metal recovery.
- •Verify glazing U-values meet or exceed building regs.
Indicative Health & Indoor Air
Factory-finished timber/aluminium; low-maintenance and durable.
Specification
- Range
- VELFAC 200
- Collection
- VELFAC 200
- Finish
- Composite timber/aluminium window
- Thermal
- U-value 1.5 W/m²K (Plus); down to 0.8 W/m²K (ENERGY triple-glazed)
- Service life
- 40 years