Steni Vision
Digitally printed stone-composite panel for bespoke facade imagery. At 17.2 kgCO₂e/m² it declares the same figure as the plain through-coloured Steni Colour, so on this evidence the printed surface carries no measurable carbon penalty.

Carbon and evidence
Product Evidence
Evidence currently held for the STENI product record.
Recorded Carbon Result
A1–A3 GWP-total per 1 m² of panel, as declared in NEPD-14676-15302. Module D (-18.2) is excluded from this figure.
Indicator: GWP-total
Steni Vision Environmental Product Declaration · NEPD-14676-15302, LCA results, GWP-total row, A1-A3 columnA1–A3 covers raw-material supply, transport to manufacture and manufacturing. It is product-stage information, not a whole-life result.
Environmental Product Declaration
EPD recorded- Coverage
- Specific product
- Declared unit
- 1 m² of panel
- Programme
- The Norwegian EPD Foundation (EPD Norge / EPD-Global)
- Registration
- NEPD-14676-15302
- Standard
- EN 15804+A2
- Valid until
- 2031-01-19
- Verification
- Third-party verified
Reported GWP Modules
Displayed as stored; modules are not added together here.
A1–A3
17.2 kgCO₂e
per 1 m² of panel
Sourced Product Claims
- Third-party verified EPD (NEPD-14676-15302)Third-party verifiedSource
Evidence Sources
The Norwegian EPD Foundation (EPD Norge / EPD-Global) · NEPD-14676-15302, LCA results, GWP-total row, A1-A3 column
Coverage: 1 m² of panel
Comparison Status
This result should be displayed for information only and not ranked against another product.
- • The PCR and version are missing.
Design & Specification Notes
Qualitative notes for early design discussion. Not product-specific EPD evidence, and not a basis for numerical comparison.
Digitally printed stone-composite panel for bespoke facade imagery.
Typical Uses
- •Facade cladding
- •Weather protection
- •External accents
Key Performance
Weather-resistant finish for facade exposure.
Typical Service-Life Estimate
40 yearsGeneric estimate for early design discussion; confirm with the manufacturer.
Specification Actions
- •Confirm the current EPD covers the selected product, finish and manufacturing route.
- •Calculate transport distances for primary materials.
- •Document material reuse or reclaimed content percentages.
Indicative Health & Indoor Air
Specification
- Range
- Vision
- Finish
- Digitally printed stone-composite panel