Steni Colour Reuse — Reused Panel

A reclaimed Steni Colour panel, recovered and re-certified for a second installation. It declares 1.55 kgCO₂e/m² against 17.2 for the equivalent new panel — an 11-fold reduction, on an identical declared unit, from the same manufacturer. Its A1–A3 covers reprocessing rather than manufacture, which is why the fossil term is small but not zero.

Manufacturer page
STENI Steni Colour Reuse — Reused Panel

Carbon and evidence

Product Evidence

Evidence currently held for the STENI product record.

STENI

Recorded Carbon Result

1.55kgCO₂e/m²

A1–A3 GWP-total per 1 m² of reused panel, as declared in NEPD-14592-15187. Module D (-43.9) is excluded from this figure.

Indicator: GWP-total

Steni Colour Reuse — Reused Panel Environmental Product Declaration · NEPD-14592-15187, LCA results, GWP-total row, A1-A3 column

A1–A3 covers raw-material supply, transport to manufacture and manufacturing. It is product-stage information, not a whole-life result.

Environmental Product Declaration

EPD recorded
Coverage
Specific product
Declared unit
1 m² of reused panel
Programme
The Norwegian EPD Foundation (EPD Norge / EPD-Global)
Registration
NEPD-14592-15187
Standard
EN 15804+A2
Valid until
2031-01-05
Verification
Third-party verified
Read the EPDSource: NEPD-14592-15187, LCA results, GWP-total row, A1-A3 column

Reported GWP Modules

Displayed as stored; modules are not added together here.

A1–A3

1.55 kgCO₂e

per 1 m² of reused panel

* A4/A5 are EPD scenarios, not project-specific results. Module nomenclature follows BS EN 15978 / EN 15804. Declared values are suitable as inputs to a whole life carbon assessment under the RICS Professional Standard (2nd edition); this panel is not an assessment.

Sourced Product Claims

  • Third-party verified EPD (NEPD-14592-15187)Third-party verifiedSource
  • Compare with steni-colour (17.2 kgCO2e/m²) — the new version of this same panel. The pair share a declared unit and are directly comparable.Third-party verifiedSource

Evidence Sources

Steni Colour Reuse — Reused Panel Environmental Product Declaration

The Norwegian EPD Foundation (EPD Norge / EPD-Global) · NEPD-14592-15187, LCA results, GWP-total row, A1-A3 column

Coverage: 1 m² of reused panel

Third-party verified

Comparison Status

This result should be displayed for information only and not ranked against another product.

  • • The PCR and version are missing.

Design & Specification Notes

Qualitative notes for early design discussion. Not product-specific EPD evidence, and not a basis for numerical comparison.

A reclaimed Steni Colour panel, recovered and re-certified for a second installation.

Typical Uses

  • Facade cladding
  • Weather protection
  • External accents

Key Performance

Weather-resistant finish for facade exposure.

Typical Service-Life Estimate

40 years

Generic estimate for early design discussion; confirm with the manufacturer.

Specification Actions

  • Confirm the current EPD covers the selected product, finish and manufacturing route.
  • Calculate transport distances for primary materials.
  • Document material reuse or reclaimed content percentages.

Indicative Health & Indoor Air

low Risk
Evidence:Third-party verified

Specification

Range
Colour Reuse
Finish
Reclaimed and re-certified stone-composite facade panel

Cookies — essential ones keep the site working; optional analytics help us improve it. No advertising cookies.