Steni Colour
Fibreglass-reinforced stone composite panel with a crushed-stone core and a through-coloured surface, 6 mm and about 12 kg/m². The baseline against which Steni Colour Reuse should be read: the reclaimed version of this same panel declares 1.55 kgCO₂e/m².

Carbon and evidence
Product Evidence
Evidence currently held for the STENI product record.
Recorded Carbon Result
A1–A3 GWP-total per 1 m² of panel, 6 mm, approx. 12 kg/m², as declared in NEPD-14593-15186. Module D (-39.7) is excluded from this figure.
Indicator: GWP-total
Steni Colour Environmental Product Declaration · NEPD-14593-15186, LCA results, GWP-total row, A1-A3 columnA1–A3 covers raw-material supply, transport to manufacture and manufacturing. It is product-stage information, not a whole-life result.
Environmental Product Declaration
EPD recorded- Coverage
- Specific product
- Declared unit
- 1 m² of panel, 6 mm, approx. 12 kg/m²
- Programme
- The Norwegian EPD Foundation (EPD Norge / EPD-Global)
- Registration
- NEPD-14593-15186
- Standard
- EN 15804+A2
- Valid until
- 2031-01-05
- Verification
- Third-party verified
Reported GWP Modules
Displayed as stored; modules are not added together here.
A1–A3
17.2 kgCO₂e
per 1 m² of panel, 6 mm, approx. 12 kg/m²
Evidence Sources
The Norwegian EPD Foundation (EPD Norge / EPD-Global) · NEPD-14593-15186, LCA results, GWP-total row, A1-A3 column
Coverage: 1 m² of panel, 6 mm, approx. 12 kg/m²
Comparison Status
This result should be displayed for information only and not ranked against another product.
- • The PCR and version are missing.
Design & Specification Notes
Qualitative notes for early design discussion. Not product-specific EPD evidence, and not a basis for numerical comparison.
Fibreglass-reinforced stone composite panel with a crushed-stone core and a through-coloured surface, 6 mm and about 12 kg/m².
Typical Uses
- •Facade cladding
- •Weather protection
- •External accents
Key Performance
Weather-resistant finish for facade exposure.
Typical Service-Life Estimate
40 yearsGeneric estimate for early design discussion; confirm with the manufacturer.
Specification Actions
- •Confirm the current EPD covers the selected product, finish and manufacturing route.
- •Calculate transport distances for primary materials.
- •Document material reuse or reclaimed content percentages.
Indicative Health & Indoor Air
Specification
- Range
- Colour
- Finish
- Through-coloured stone-composite facade panel