SOPRALENE FLAM 180 AF

Soprema’s core torch-applied reinforced bitumen cap sheet: elastomer-modified bitumen on a 180 g/m² non-woven polyester reinforcement, slate-finished. Part of the SOPRALENE FLAM multi-layer family with 250, GARDEN and VENTI variants.

Manufacturer page
Soprema SOPRALENE FLAM 180 AF

Carbon and evidence

Product Evidence

Evidence currently held for the Soprema product record.

Soprema

Recorded Carbon Result

2.05kgCO₂e/m²

A1–A3 GWP-total per m² of SOPRALENE FLAM 180 (4.073 kg/m²), per EPD-IES-0016206 — declared for the film-faced FLAM 180 from the Polish plant, not the UK AF variant specifically

Indicator: GWP-total

A1–A3 covers raw-material supply, transport to manufacture and manufacturing. It is product-stage information, not a whole-life result.

Environmental Product Declaration

EPD recorded
Coverage
Specific product
Declared unit
1 m² SOPRALENE FLAM 180 at factory gate (4.073 kg)
Programme
The International EPD System (EPD International AB)
Registration
EPD-IES-0016206
Standard
EN 15804+A2
Valid until
2029-08-26
Verification
Third-party verified

Two caveats, stated rather than smoothed over: the declaring plant is Soprema Polska (Błonie), scope Poland/Europe, and UK supply plant is unverified; and the declared product is FLAM 180 (thermofusible film both faces) while the UK sells the slate-finished AF variant. Reference service life 70 years, conditional on a suitable top layer.

Reported GWP Modules

Displayed as stored; modules are not added together here.

A1–A3

2.05 kgCO₂e

per 1 m² SOPRALENE FLAM 180 (4.073 kg)

* A4/A5 are EPD scenarios, not project-specific results. Module nomenclature follows BS EN 15978 / EN 15804. Declared values are suitable as inputs to a whole life carbon assessment under the RICS Professional Standard (2nd edition); this panel is not an assessment.

Comparison Status

This result should be displayed for information only and not ranked against another product.

  • • The PCR and version are missing.
  • • The carbon result is not linked to an evidence source.
  • • The EPD is not linked to an evidence source.

Evidence Gaps

  • No product-specific circularity or material-health claims are recorded.

Design & Specification Notes

Qualitative notes for early design discussion. Not product-specific EPD evidence, and not a basis for numerical comparison.

Soprema’s core torch-applied reinforced bitumen cap sheet: elastomer-modified bitumen on a 180 g/m² non-woven polyester reinforcement, slate-finished.

Typical Uses

  • Roof coverings
  • Waterproofing layer
  • Weather protection

Key Performance

High durability in wet exposure and wind uplift.

Typical Service-Life Estimate

40 years

Generic estimate for early design discussion; confirm with the manufacturer.

Specification Actions

  • Confirm the current EPD covers the selected product, finish and manufacturing route.
  • Calculate transport distances for primary materials.
  • Document material reuse or reclaimed content percentages.

Indicative Health & Indoor Air

low Risk

Installation risks (torch application, hot works, resin handling) are the installer’s to manage; follow the current manufacturer guidance.

Evidence:Third-party verified

Specification

Finish
Torch-on SBS elastomeric bitumen cap sheet, slate finished