Smart Alitherm 800

The heavy-duty Alitherm for larger openings and commercial use: dual polyamide thermal breaks to 1.3 W/m²K with the correct glass unit, WER A capable. Note: the 800 is not among the five Alitherm systems holding Cradle to Cradle Bronze.

Manufacturer page
Smart Systems Smart Alitherm 800

Carbon and evidence

Product Evidence

Evidence currently held for the Smart Systems product record.

Smart Systems

Recorded Carbon Result

99.2kgCO₂e/m²

A1–A3 GWP-total per m² of the CAB industry-average side-hung aluminium window system (1.23 × 1.48 m, standard double glazed), per EPD-2023-0014 — a UK sector average Smart is an approved user of, NOT a Smart-specific figure. Enhanced/triple variants run to 121.

Indicator: GWP-total

A1–A3 covers raw-material supply, transport to manufacture and manufacturing. It is product-stage information, not a whole-life result.

Environmental Product Declaration

EPD recorded
Coverage
Representative product
Declared unit
1 m² of side-hung / top-hung aluminium window system (four representative 1.23 × 1.48 m windows)
Programme
European Aluminium AISBL (owner: Council for Aluminium in Building)
Registration
EPD-2023-0014
Standard
EN 15804+A2 (+ EN 17213, European Aluminium PCR 03/2020)
Valid until
2028-09-20
Verification
Third-party verified

CAB association EPD representative of >50% of the UK market — not a Smart-specific declaration; Smart’s CAB approval letter is bundled into the PDF they host. Four representative windows: side hung standard 99.2 / top hung standard 105 / side hung enhanced (triple) 117 / top hung enhanced 121 kgCO2e per m². The EPD’s own disclaimer: it "cannot be used as a guarantee of the recycled content of the actual product sold on the market" — and Smart’s published billet sources are primary smelters, so no recycled-content claim is recorded here.

Reported GWP Modules

Displayed as stored; modules are not added together here.

A1–A3

99.2 kgCO₂e

per 1 m² of 1.23 × 1.48 m side-hung window system, standard double glazed

* A4/A5 are EPD scenarios, not project-specific results. Module nomenclature follows BS EN 15978 / EN 15804. Declared values are suitable as inputs to a whole life carbon assessment under the RICS Professional Standard (2nd edition); this panel is not an assessment.

Service Life — the B4 Replacement Input

40 years · manufacturer declared

≈2 installations over a 60-year building study period.

B4 (replacement) follows the building, not the product: an assessor multiplies replacement cycles by project quantities. This record supplies the service life and does not compute B4.

1 certification is held in the staging record but not presented as product evidence because an exact public source has not yet been mapped.

Comparison Status

This result should be displayed for information only and not ranked against another product.

  • • The PCR and version are missing.
  • • The carbon result is not linked to an evidence source.
  • • The EPD is not linked to an evidence source.

Evidence Gaps

  • No A4–D lifecycle results are held beyond the product stage.
  • No product-specific circularity or material-health claims are recorded.
  • 1 certification is withheld because exact public evidence is not mapped.

Design & Specification Notes

Qualitative notes for early design discussion. Not product-specific EPD evidence, and not a basis for numerical comparison.

The heavy-duty Alitherm for larger openings and commercial use: dual polyamide thermal breaks to 1.

Typical Uses

  • Glazing systems
  • Daylight openings
  • Thermal envelope

Key Performance

Supports daylight and thermal performance of the envelope.

Specification Actions

  • Verify glazing U-values meet or exceed building regs.
  • Consider specifying higher recycled glass content.
  • Confirm the current EPD covers the selected product, finish and manufacturing route.

Indicative Health & Indoor Air

low Risk
Evidence:Third-party verified

Specification

Finish
Thermally broken aluminium window, polyester powder coat
Thermal
Uw 1.3 W/m²K (with correct glass unit)
Service life
40 years

Cookies — essential ones keep the site working; optional analytics help us improve it. No advertising cookies.