Rieder concrete skin / öko skin

Glassfibre-reinforced concrete facade panel, 13 mm, used as a rainscreen. Its A4 and A5 modules are not declared, so there is no cradle-to-site figure.

Manufacturer page
Rieder Rieder concrete skin / öko skin

Carbon and evidence

Product Evidence

Evidence currently held for the Rieder product record.

Rieder

Recorded Carbon Result

21.3kgCO₂e/m²

A1–A3 GWP-total per 1 m² of glassfibre-reinforced concrete facade slab, 13 mm, 28.73 kg/m², as declared in EPD-RSE-20250354-IBI3-EN. Module D (-0.613) is excluded from this figure.

Indicator: GWP-total

Rieder concrete skin / öko skin Environmental Product Declaration · EPD-RSE-20250354-IBI3-EN, p. 6, section 5 LCA: Results, environmental impact table, GWP-total row, A1-A3 column (read from a 150 dpi render — the PDF has no text layer)

A1–A3 covers raw-material supply, transport to manufacture and manufacturing. It is product-stage information, not a whole-life result.

Environmental Product Declaration

EPD recorded
Coverage
Product family
Declared unit
1 m² of glassfibre-reinforced concrete facade slab, 13 mm, 28.73 kg/m²
Programme
Institut Bauen und Umwelt e.V. (IBU)
Registration
EPD-RSE-20250354-IBI3-EN
Standard
EN 15804+A2
Valid until
2030-09-15
Verification
Third-party verified

Declared as a representative average across concrete skin and öko skin in Matrix 2.2. The declaration states product-level deviations from the average are mostly under 5% for A1–A3, but exceed 10% for ADPE and GWP-luluc.

Read the EPDSource: EPD-RSE-20250354-IBI3-EN, p. 6, section 5 LCA: Results, environmental impact table, GWP-total row, A1-A3 column (read from a 150 dpi render — the PDF has no text layer)

Carbon profile

kgCO2e per 1 m² of glassfibre-reinforced concrete facade slab, 13 mm, 28.73 kg/m² · each bar starts at zero · local scale

A1-A3 product

21.3

A4-A5 site*

not declared

B use

not declared

C end of life

0.761

D reuse / recycling

not declared

adds carbon stores or removes EPD scenario* reuse/recycling potential (D)
* EPD transport and installation scenario, not this project's. Not declared: site, use, reuse / recycling. Do not compare bar lengths between materials. Each chart may use a different scale and declared unit.

Reported GWP Modules

Displayed as stored; modules are not added together here.

A1–A3

21.3 kgCO₂e

per 1 m² of glassfibre-reinforced concrete facade slab, 13 mm, 28.73 kg/m²

A4*

not declared

per 1 m² of glassfibre-reinforced concrete facade slab, 13 mm, 28.73 kg/m²

A5*

not declared

per 1 m² of glassfibre-reinforced concrete facade slab, 13 mm, 28.73 kg/m²

B1

not declared

per 1 m² of glassfibre-reinforced concrete facade slab, 13 mm, 28.73 kg/m²

B2

not declared

per 1 m² of glassfibre-reinforced concrete facade slab, 13 mm, 28.73 kg/m²

B6

not declared

per 1 m² of glassfibre-reinforced concrete facade slab, 13 mm, 28.73 kg/m²

B7

not declared

per 1 m² of glassfibre-reinforced concrete facade slab, 13 mm, 28.73 kg/m²

C1

0.0182 kgCO₂e

per 1 m² of glassfibre-reinforced concrete facade slab, 13 mm, 28.73 kg/m²

C2

0.292 kgCO₂e

per 1 m² of glassfibre-reinforced concrete facade slab, 13 mm, 28.73 kg/m²

C3

0.0173 kgCO₂e

per 1 m² of glassfibre-reinforced concrete facade slab, 13 mm, 28.73 kg/m²

C4

0.434 kgCO₂e

per 1 m² of glassfibre-reinforced concrete facade slab, 13 mm, 28.73 kg/m²

* A4/A5 are EPD scenarios, not project-specific results. Module nomenclature follows BS EN 15978 / EN 15804. Declared values are suitable as inputs to a whole life carbon assessment under the RICS Professional Standard (2nd edition); this panel is not an assessment.

Sourced Product Claims

  • Third-party verified EPD (EPD-RSE-20250354-IBI3-EN)Third-party verifiedSource

Evidence Sources

Rieder concrete skin / öko skin Environmental Product Declaration

Institut Bauen und Umwelt e.V. (IBU) · EPD-RSE-20250354-IBI3-EN, p. 6, section 5 LCA: Results, environmental impact table, GWP-total row, A1-A3 column (read from a 150 dpi render — the PDF has no text layer)

Coverage: Declared as a representative average across concrete skin and öko skin in Matrix 2.2. The declaration states product-level deviations from the average are mostly under 5% for A1–A3, but exceed 10% for ADPE and GWP-luluc.

Third-party verified

Comparison Status

This result should be displayed for information only and not ranked against another product.

  • • The PCR and version are missing.

Design & Specification Notes

Qualitative notes for early design discussion. Not product-specific EPD evidence, and not a basis for numerical comparison.

Glassfibre-reinforced concrete facade panel, 13 mm, used as a rainscreen.

Typical Uses

  • Facade cladding
  • Weather protection
  • External accents

Key Performance

Weather-resistant finish for facade exposure.

Typical Service-Life Estimate

40 years

Generic estimate for early design discussion; confirm with the manufacturer.

Specification Actions

  • Specify GGBS/PFA cement replacement (target: 50%+ replacement).
  • Request EPD showing embodied carbon per m3.
  • Calculate transport distances for primary materials.

Indicative Health & Indoor Air

low Risk
Evidence:Third-party verified

Specification

Range
concrete skin / öko skin
Finish
Glassfibre-reinforced concrete facade panel

Cookies — essential ones keep the site working; optional analytics help us improve it. No advertising cookies.