SC804 Intumescent Steel Coating

A water-based, borate-free, APEO-free thin-film intumescent basecoat for internal structural steelwork, optimised for 90 minutes and tested up to 120 minutes fire resistance. Used on steel, cast iron, galvanised steel and concrete members. Very low VOC. Supplied white; the finished colour of exposed steelwork comes from a decorative topseal over it, not from this product.

Manufacturer page
Nullifire SC804 Intumescent Steel Coating

Carbon and evidence

Product Evidence

Evidence currently held for the Nullifire product record.

Nullifire

Recorded Carbon Result

2.29kgCO₂e/kg

A1–A3 GWP-total per 1 kg of coating (average declaration, 5% product variation)

A1–A3 covers raw-material supply, transport to manufacture and manufacturing. It is product-stage information, not a whole-life result.

Environmental Product Declaration

EPD recorded
Coverage
Manufacturer average
Declared unit
1 kg of coating
Programme
EPD International AB (The International EPD® System)
Registration
EPD-IES-0013759:001 (S-P-13759)
Standard
EN 15804:2012+A2:2019/AC:2021
Valid until
2029-05-15
Verification
Third-party verified

Average declaration covering SC802, SC803 and SC804; stated GWP variation across those products is 5%. Published 2024-05-16. A4–A5 and B1–B7 are Not Declared. A3 modelled for the UK market. Declared per 1 kg of coating, as published. Converting to kgCO2e/m² of steel requires the dry film thickness for the section factor and fire period actually specified — a project quantity that a palette does not hold. Never add this figure to the steel section figure: the two are declared against different units.

Read the EPDSource: Results per declared unit, mandatory indicators table, p. 9

Carbon profile

kgCO2e per 1 kg · each bar starts at zero · local scale

A1-A3 product

2.29

A4-A5 site*

not declared

B use

not declared

C end of life

2.46

D reuse / recycling

0

End of life is the largest of the modules this EPD declares.

adds carbon stores or removes EPD scenario* reuse/recycling potential (D)
* EPD transport and installation scenario, not this project's. Not declared: site, use. Module D shows potential impacts or benefits from reuse, recovery or recycling after the product's assessed life. It is reported separately and never added to A-C. Do not compare bar lengths between materials. Each chart may use a different scale and declared unit.

Reported GWP Modules

Displayed as stored; modules are not added together here.

A1–A3

2.29 kgCO₂e

per 1 kg

A4*

not captured

per 1 kg

A5*

not captured

per 1 kg

B1–B7

not captured

per 1 kg

C1

0 kgCO₂e

per 1 kg

C2

<0.001 kgCO₂e

per 1 kg

C3

0 kgCO₂e

per 1 kg

C4

2.46 kgCO₂e

per 1 kg

D

0 kgCO₂e

per 1 kg

* A4/A5 are EPD scenarios, not project-specific results. Module D is outside the A–C system boundary and is not added to A–C. Module nomenclature follows BS EN 15978 / EN 15804. Declared values are suitable as inputs to a whole life carbon assessment under the RICS Professional Standard (2nd edition); this panel is not an assessment.

1 claim is held in the staging record but not presented as product evidence because an exact public source has not yet been mapped.

Comparison Status

This result should be displayed for information only and not ranked against another product.

  • • The PCR and version are missing.
  • • The GWP indicator is missing.
  • • The carbon result is not linked to an evidence source.
  • • The EPD is not linked to an evidence source.

Evidence Gaps

  • 1 sustainability claim is withheld because exact public evidence is not mapped.

Design & Specification Notes

Qualitative notes for early design discussion. Not product-specific EPD evidence, and not a basis for numerical comparison.

A water-based, borate-free, APEO-free thin-film intumescent basecoat for internal structural steelwork, optimised for 90 minutes and tested up to 120 minutes fire resistance.

Typical Uses

  • Primary frame
  • Long-span elements
  • Load-bearing supports

Key Performance

High load-bearing capacity for primary frame.

Typical Service-Life Estimate

60 years

Generic estimate for early design discussion; confirm with the manufacturer.

Specification Actions

  • Confirm the current EPD covers the selected steel product and manufacturing route.
  • Verify recycled content and the steel manufacturing route with supplier evidence.
  • Calculate transport distances for primary materials.

Indicative Health & Indoor Air

low Risk

Water-based and very low VOC. Consult the manufacturer safety data sheet for handling and PPE.

Evidence:Third-party verified

Specification

Product code
SC804
Collection
Steel coatings
Finish
Water-based thin-film intumescent basecoat — supplied white
Fire rating
Optimised for 90 minutes and tested up to 120 minutes fire resistance. The period achieved depends on the dry film thickness applied for the section factor of each member — read from the project loading schedule, never assumed.