Marley Clay Roof Tile

Fired-clay roof tiles for pitched roofs — plain and interlocking (Acme Single & Double Camber, Canterbury, Hawkins and others). Natural, colour-fast fired clay with a long service life; kilns partly biomass-fired, giving a lower net product-stage footprint than the fossil figure alone.

Manufacturer page
Marley Marley Clay Roof Tile

Carbon and evidence

Product Evidence

Evidence currently held for the Marley product record.

Marley

Recorded Carbon Result

4.75kgCO₂e/m²

A1–A3 GWP-total per m² of roof, per EPD THIS FIGURE IS FORMAT-SPECIFIC — small-format plain tile, 60 tiles/m², 64 kg/m². Pantiles (16.25 tiles/m², 43 kg/m²) are 3.33 — 33% below the figure on this record.

A1–A3 covers raw-material supply, transport to manufacture and manufacturing. It is product-stage information, not a whole-life result.

Environmental Product Declaration

EPD recorded
Coverage
Product family
Declared unit
1 m² of roof (64 kg)
Programme
EPD Hub
Registration
HUB-1593
Standard
EN 15804+A2
Valid until
2029-06-13
Verification
Third-party verified

This figure is format-specific: it is the small-format plain tile, 60 tiles/m² at 64 kg/m², declared in HUB-1593. The declaration carries a conversion table for alternative tile sizes and the other formats differ materially — pantiles, at 16.25 tiles/m² and 43 kg/m², come to 3.33. Tile format rather than tile material is the dominant variable in a tiled roof’s carbon per square metre.

Carbon profile

kgCO2e per 1 m² of roof · each bar starts at zero · local scale

A1-A3 product

4.75

A4-A5 site*

3.63

B use

not declared

C end of life

0.874

D reuse / recycling

-1.11

adds carbon stores or removes EPD scenario* reuse/recycling potential (D)
* EPD transport and installation scenario, not this project's. Not declared: use. Module D shows potential impacts or benefits from reuse, recovery or recycling after the product's assessed life. It is reported separately and never added to A-C. Do not compare bar lengths between materials. Each chart may use a different scale and declared unit.

Reported GWP Modules

Displayed as stored; modules are not added together here.

A1–A3

4.75 kgCO₂e

per 1 m² of roof

A4*

1.06 kgCO₂e

per 1 m² of roof

A5*

2.57 kgCO₂e

per 1 m² of roof

C1

0 kgCO₂e

per 1 m² of roof

C2

0.279 kgCO₂e

per 1 m² of roof

C3

0.557 kgCO₂e

per 1 m² of roof

C4

0.0378 kgCO₂e

per 1 m² of roof

D

-1.11 kgCO₂e

per 1 m² of roof

* A4/A5 are EPD scenarios, not project-specific results. Module D is outside the A–C system boundary and is not added to A–C. Module nomenclature follows BS EN 15978 / EN 15804. Declared values are suitable as inputs to a whole life carbon assessment under the RICS Professional Standard (2nd edition); this panel is not an assessment.

Upfront Carbon (A1–A5)*

8.38 kgCO₂e per 1 m² of roof

A1–A3 4.75 + A4 1.06 + A5 2.57 · as declared

* Includes the EPD’s A4/A5 scenario assumptions, not project-specific transport or installation. This is the aggregation the proposed Part Z applies upfront limits to.

Service Life — the B4 Replacement Input

60 years · EPD reference service life

≈1 installation over a 60-year building study period.

B4 (replacement) follows the building, not the product: an assessor multiplies replacement cycles by project quantities. This record supplies the service life and does not compute B4.

2 claims and 2 certifications are held in the staging record but not presented as product evidence because an exact public source has not yet been mapped.

Comparison Status

This result should be displayed for information only and not ranked against another product.

  • • The PCR and version are missing.
  • • The GWP indicator is missing.
  • • The carbon result is not linked to an evidence source.
  • • The EPD is not linked to an evidence source.

Evidence Gaps

  • 2 sustainability claims are withheld because exact public evidence is not mapped.
  • 2 certifications are withheld because exact public evidence is not mapped.

Design & Specification Notes

Qualitative notes for early design discussion. Not product-specific EPD evidence, and not a basis for numerical comparison.

Fired-clay roof tiles for pitched roofs — plain and interlocking (Acme Single & Double Camber, Canterbury, Hawkins and others).

Typical Uses

  • Roof coverings
  • Waterproofing layer
  • Weather protection

Key Performance

High durability in wet exposure and wind uplift.

Specification Actions

  • Confirm the current EPD covers the selected product, finish and manufacturing route.
  • Calculate transport distances for primary materials.
  • Document material reuse or reclaimed content percentages.

Indicative Health & Indoor Air

low Risk

Inert fired-clay tile; standard cutting-dust (silica) precautions when cutting.

Evidence:Third-party verified

Specification

Range
Acme / Canterbury / Hawkins
Collection
Clay Roof Tiles
Finish
Clay roof tile (plain & interlocking)
Service life
60 years

Cookies — essential ones keep the site working; optional analytics help us improve it. No advertising cookies.