Lindner LOOP prime / LOOP aurum Refurbished Raised Floor

Raised access floor panel refurbished from recovered NORTEC panels, declared at 1.43 kgCO₂e/m² including subconstruction. A reuse product declared against its own EPD rather than a new-product figure.

Manufacturer page
Lindner Group Lindner LOOP prime / LOOP aurum Refurbished Raised Floor

Carbon and evidence

Product Evidence

Evidence currently held for the Lindner Group product record.

Lindner Group

Recorded Carbon Result

1.43kgCO₂e/m²

A1–A3 GWP-total per 1 m² of refurbished raised floor panel, 58.7 kg/m² including subconstruction, as declared in EPD-LIN-20240490-CBB1-EN. Module D (-0.0703) is excluded.

Indicator: GWP-total

Lindner LOOP prime / LOOP aurum Refurbished Raised Floor Environmental Product Declaration · EPD-LIN-20240490-CBB1-EN

A1–A3 covers raw-material supply, transport to manufacture and manufacturing. It is product-stage information, not a whole-life result.

Environmental Product Declaration

EPD recorded
Coverage
Product family
Declared unit
1 m² of refurbished raised floor panel, 58.7 kg/m² including subconstruction
Programme
Institut Bauen und Umwelt e.V. (IBU)
Registration
EPD-LIN-20240490-CBB1-EN
Standard
EN 15804+A2
Valid until
2030-06-10
Verification
Third-party verified

Refurbished NORTEC panels, 39 mm at 1,500 kg/m³ bulk density. Lindner designate Scenario 0 (reuse) as the default. C1 is modelled on the worst case — the reuse scenario requires non-destructive demounting with electrical cutting, whereas the two disposal scenarios have C1 = 0.

Read the EPDSource: EPD-LIN-20240490-CBB1-EN

Reported GWP Modules

Displayed as stored; modules are not added together here.

A1–A3

1.43 kgCO₂e

per 1 m² of refurbished raised floor panel, 58.7 kg/m² including subconstruction

* A4/A5 are EPD scenarios, not project-specific results. Module nomenclature follows BS EN 15978 / EN 15804. Declared values are suitable as inputs to a whole life carbon assessment under the RICS Professional Standard (2nd edition); this panel is not an assessment.

Sourced Product Claims

  • Third-party verified EPD (EPD-LIN-20240490-CBB1-EN)Third-party verifiedSource

Evidence Sources

Lindner LOOP prime / LOOP aurum Refurbished Raised Floor Environmental Product Declaration

Institut Bauen und Umwelt e.V. (IBU) · EPD-LIN-20240490-CBB1-EN

Coverage: Refurbished NORTEC panels, 39 mm at 1,500 kg/m³ bulk density. Lindner designate Scenario 0 (reuse) as the default. C1 is modelled on the worst case — the reuse scenario requires non-destructive demounting with electrical cutting, whereas the two disposal scenarios have C1 = 0.

Third-party verified

Comparison Status

This result should be displayed for information only and not ranked against another product.

  • • The PCR and version are missing.

Design & Specification Notes

Qualitative notes for early design discussion. Not product-specific EPD evidence, and not a basis for numerical comparison.

Raised access floor panel refurbished from recovered NORTEC panels, declared at 1.

Typical Uses

  • Primary flooring
  • High-traffic circulation
  • Work areas

Key Performance

Hard-wearing surface for high footfall.

Typical Service-Life Estimate

25 years

Generic estimate for early design discussion; confirm with the manufacturer.

Specification Actions

  • Confirm the current EPD covers the selected product, finish and manufacturing route.
  • Calculate transport distances for primary materials.
  • Document material reuse or reclaimed content percentages.

Indicative Health & Indoor Air

low Risk
Evidence:Third-party verified

Specification

Range
LOOP
Finish
Refurbished raised access floor panel

Cookies — essential ones keep the site working; optional analytics help us improve it. No advertising cookies.