Lindner LOOP prime / LOOP aurum Refurbished Raised Floor
Raised access floor panel refurbished from recovered NORTEC panels, declared at 1.43 kgCO₂e/m² including subconstruction. A reuse product declared against its own EPD rather than a new-product figure.

Carbon and evidence
Product Evidence
Evidence currently held for the Lindner Group product record.
Recorded Carbon Result
A1–A3 GWP-total per 1 m² of refurbished raised floor panel, 58.7 kg/m² including subconstruction, as declared in EPD-LIN-20240490-CBB1-EN. Module D (-0.0703) is excluded.
Indicator: GWP-total
Lindner LOOP prime / LOOP aurum Refurbished Raised Floor Environmental Product Declaration · EPD-LIN-20240490-CBB1-ENA1–A3 covers raw-material supply, transport to manufacture and manufacturing. It is product-stage information, not a whole-life result.
Environmental Product Declaration
EPD recorded- Coverage
- Product family
- Declared unit
- 1 m² of refurbished raised floor panel, 58.7 kg/m² including subconstruction
- Programme
- Institut Bauen und Umwelt e.V. (IBU)
- Registration
- EPD-LIN-20240490-CBB1-EN
- Standard
- EN 15804+A2
- Valid until
- 2030-06-10
- Verification
- Third-party verified
Refurbished NORTEC panels, 39 mm at 1,500 kg/m³ bulk density. Lindner designate Scenario 0 (reuse) as the default. C1 is modelled on the worst case — the reuse scenario requires non-destructive demounting with electrical cutting, whereas the two disposal scenarios have C1 = 0.
Reported GWP Modules
Displayed as stored; modules are not added together here.
A1–A3
1.43 kgCO₂e
per 1 m² of refurbished raised floor panel, 58.7 kg/m² including subconstruction
Sourced Product Claims
- Third-party verified EPD (EPD-LIN-20240490-CBB1-EN)Third-party verifiedSource
Evidence Sources
Institut Bauen und Umwelt e.V. (IBU) · EPD-LIN-20240490-CBB1-EN
Coverage: Refurbished NORTEC panels, 39 mm at 1,500 kg/m³ bulk density. Lindner designate Scenario 0 (reuse) as the default. C1 is modelled on the worst case — the reuse scenario requires non-destructive demounting with electrical cutting, whereas the two disposal scenarios have C1 = 0.
Comparison Status
This result should be displayed for information only and not ranked against another product.
- • The PCR and version are missing.
Design & Specification Notes
Qualitative notes for early design discussion. Not product-specific EPD evidence, and not a basis for numerical comparison.
Raised access floor panel refurbished from recovered NORTEC panels, declared at 1.
Typical Uses
- •Primary flooring
- •High-traffic circulation
- •Work areas
Key Performance
Hard-wearing surface for high footfall.
Typical Service-Life Estimate
25 yearsGeneric estimate for early design discussion; confirm with the manufacturer.
Specification Actions
- •Confirm the current EPD covers the selected product, finish and manufacturing route.
- •Calculate transport distances for primary materials.
- •Document material reuse or reclaimed content percentages.
Indicative Health & Indoor Air
Specification
- Range
- LOOP
- Finish