Kingspan Kooltherm K108 Cavity Board
Fibre-free rigid phenolic insulation for partial-fill masonry cavity walls. A low-conductivity phenolic core (≈0.018 W/mK) between low-emissivity composite foil facings gives high thermal performance at reduced board thickness. Part of the Kooltherm range (K107 pitched roof / K108 cavity / K112 framing) covered by one EPD.

Carbon and evidence
Product Evidence
Evidence currently held for the Kingspan product record.
Recorded Carbon Result
A1–A3 GWP-total per m² at 100 mm, per EPD
A1–A3 covers raw-material supply, transport to manufacture and manufacturing. It is product-stage information, not a whole-life result.
Environmental Product Declaration
EPD recorded- Coverage
- Product family
- Declared unit
- 1 m² at 100 mm thickness (4.12 kg)
- Programme
- EPD Hub
- Registration
- HUB-5558
- Standard
- EN 15804+A2
- Valid until
- 2031-03-01
- Verification
- Third-party verified
Third-party verified (EPD Hub, verifier VP-055). Impact data at 100 mm (RD 5.25 m²K/W); scale by thickness for other boards (25–150 mm). Covers Kooltherm K107 / K108 / K112 (same phenolic core). A4/A5/B not declared; C/D shown for the current-waste-destinations end-of-life scenario.
Carbon profile
kgCO2e per 1 m² at 100 mm · each bar starts at zero · local scale
A1-A3 product
10.6
A4-A5 site*
—
B use
—
C end of life
10.4
D reuse / recycling
-0.354
Reported GWP Modules
Displayed as stored; modules are not added together here.
A1–A3
10.6 kgCO₂e
per 1 m² at 100 mm
C1
0 kgCO₂e
per 1 m² at 100 mm
C2
0.0467 kgCO₂e
per 1 m² at 100 mm
C3
10.3 kgCO₂e
per 1 m² at 100 mm
C4
0.0496 kgCO₂e
per 1 m² at 100 mm
D
-0.354 kgCO₂e
per 1 m² at 100 mm
Service Life — the B4 Replacement Input
60 years · EPD reference service life
≈1 installation over a 60-year building study period.
2 claims and 1 certification are held in the staging record but not presented as product evidence because an exact public source has not yet been mapped.
Comparison Status
This result should be displayed for information only and not ranked against another product.
- • The GWP indicator is missing.
- • The carbon result is not linked to an evidence source.
- • The EPD is not linked to an evidence source.
Evidence Gaps
- •2 sustainability claims are withheld because exact public evidence is not mapped.
- •1 certification is withheld because exact public evidence is not mapped.
Design & Specification Notes
Qualitative notes for early design discussion. Not product-specific EPD evidence, and not a basis for numerical comparison.
Fibre-free rigid phenolic insulation for partial-fill masonry cavity walls.
Typical Uses
- •Thermal envelope
- •Roof/wall cavities
- •Airtightness layers
Key Performance
Good thermal resistance with reduced heat loss.
Specification Actions
- •Compare embodied carbon of insulation options (natural vs synthetic).
- •Request blowing agent GWP values for foam insulation.
- •Confirm the current EPD covers the selected product, finish and manufacturing route.
Indicative Health & Indoor Air
Fibre-free rigid phenolic insulation board; low-emissivity facings. Follow standard cutting-dust precautions.
Specification
- Range
- K108 Cavity Board
- Collection
- Kooltherm
- Finish
- Rigid phenolic cavity-wall insulation
- Thickness
- 25–150mm
- Service life
- 60 years