Ecophon Focus

Glass-wool acoustic ceiling panel with a matt Akutex FT surface, giving high sound absorption (up to Class A) in a clean white finish. The Focus family spans a range of edge profiles (A, Ds, Dg, E and others) for different grid and demountability requirements.

Manufacturer page
Ecophon Ecophon Focus

Carbon and evidence

Product Evidence

Evidence currently held for the Ecophon product record.

Ecophon

Recorded Carbon Result

1.17kgCO₂e/m²

A1–A3 GWP-total per declared unit, per EPD

Indicator: GWP-total

Ecophon Focus Environmental Product Declaration · PDF p. 16, Appendix: environmental impacts

A1–A3 covers raw-material supply, transport to manufacture and manufacturing. It is product-stage information, not a whole-life result.

Environmental Product Declaration

EPD recorded
Coverage
Representative product
Declared unit
1 m² acoustic ceiling
Programme
EPD International (environdec.com)
Registration
S-P-10606
Standard
EN 15804+A2
Valid until
2028-11-21
Verification
Third-party verified

EPD S-P-10606 is specifically for Ecophon Focus A Carbon Low, not the complete Focus family. Confirm the staged variant before launch.

Read the EPDSource: PDF p. 16, Appendix: environmental impacts

Carbon profile

kgCO2e per 1 m² acoustic ceiling · each bar starts at zero · local scale

A1-A3 product

1.17

A4-A5 site*

0.32

B use

not declared

C end of life

0.0351

D reuse / recycling

0

adds carbon stores or removes EPD scenario* reuse/recycling potential (D)
* EPD transport and installation scenario, not this project's. Not declared: use. Module D shows potential impacts or benefits from reuse, recovery or recycling after the product's assessed life. It is reported separately and never added to A-C. Do not compare bar lengths between materials. Each chart may use a different scale and declared unit.

Reported GWP Modules

Displayed as stored; modules are not added together here.

A1–A3

1.17 kgCO₂e

per 1 m² acoustic ceiling

A4*

0.0588 kgCO₂e

per 1 m² acoustic ceiling

A5*

0.261 kgCO₂e

per 1 m² acoustic ceiling

C2

0.00409 kgCO₂e

per 1 m² acoustic ceiling

C4

0.031 kgCO₂e

per 1 m² acoustic ceiling

D

0 kgCO₂e

per 1 m² acoustic ceiling

* A4/A5 are EPD scenarios, not project-specific results. Module D is outside the A–C system boundary and is not added to A–C. Module nomenclature follows BS EN 15978 / EN 15804. Declared values are suitable as inputs to a whole life carbon assessment under the RICS Professional Standard (2nd edition); this panel is not an assessment.

Upfront Carbon (A1–A5)*

1.49 kgCO₂e per 1 m² acoustic ceiling

A1–A3 1.17 + A4 0.0588 + A5 0.261 · GWP-total, as declared

* Includes the EPD’s A4/A5 scenario assumptions, not project-specific transport or installation. This is the aggregation the proposed Part Z applies upfront limits to. The A1–A3 figure includes declared biogenic storage of -0.183 kgCO₂e; Part Z aggregates upfront carbon excluding sequestered carbon, which is the assessor's adjustment to make.

Service Life — the B4 Replacement Input

50 years · EPD reference service life

≈2 installations over a 60-year building study period.

B4 (replacement) follows the building, not the product: an assessor multiplies replacement cycles by project quantities. This record supplies the service life and does not compute B4.

Sourced Product Claims

  • Third-party verified family EPDThird-party verifiedSource

2 claims are held in the staging record but not presented as product evidence because an exact public source has not yet been mapped.

Evidence Sources

Ecophon Focus product page

Ecophon

Coverage: Ecophon Focus

Manufacturer declared
Ecophon Focus Environmental Product Declaration

EPD International (environdec.com) · PDF p. 16, Appendix: environmental impacts

Coverage: EPD S-P-10606 is specifically for Ecophon Focus A Carbon Low, not the complete Focus family. Confirm the staged variant before launch.

Third-party verified

Comparison Status

The record contains the basic metadata required for a controlled comparison. Products must still perform the same function and use compatible units, PCRs and lifecycle scope.

Evidence Gaps

  • 2 sustainability claims are withheld because exact public evidence is not mapped.

Design & Specification Notes

Qualitative notes for early design discussion. Not product-specific EPD evidence, and not a basis for numerical comparison.

Glass-wool acoustic ceiling panel with a matt Akutex FT surface, giving high sound absorption (up to Class A) in a clean white finish.

Typical Uses

  • Interior ceilings
  • Acoustic control
  • Service zones

Key Performance

Confirm acoustic, fire, humidity and demountability performance for the selected ceiling system.

Specification Actions

  • Confirm the current EPD covers the selected product, finish and manufacturing route.
  • Calculate transport distances for primary materials.
  • Document material reuse or reclaimed content percentages.

Indicative Health & Indoor Air

low Risk

Glass-wool core with painted glass-tissue face; low-emitting (Focus products certified to indoor-air schemes).

Evidence:Third-party verified

Specification

Range
Ecophon Focus
Collection
Focus
Finish
Glass-wool acoustic ceiling tile
Thickness
20mm
Width
600mm
Length
600–1200mm
Fire rating
Euroclass A2-s1,d0
Acoustic rating
Sound absorption up to Class A (αw 1.00)
Service life
50 years