CIMENTO WILL

Cast concrete cladding slab in sandblasted, smooth and Rio Terà finishes, declared per square metre. Its declaration is a multi-product WORST CASE, not an average — unlike its FORMELLE sibling. End-of-life again matches production: C4 is 16.2 kgCO₂e/m² against 16.5 for A1–A3.

Manufacturer page
CIMENTO CIMENTO WILL

Carbon and evidence

Product Evidence

Evidence currently held for the CIMENTO product record.

CIMENTO

Recorded Carbon Result

16.5kgCO₂e/m²

A1–A3 GWP-total per 1 m² of CIMENTO® WILL cladding slab, excluding packaging (5 kg/m² at 2.5 mm; 11.3 kg/m² at 8 mm), as declared in EPD-IES-0017894:001. Multi-product WORST CASE across the included products. The declaration forbids using A1–A3 without module C; whole-life across the declared modules is 39 kgCO2e/m².

Indicator: GWP-total

CIMENTO WILL Environmental Product Declaration · EPD-IES-0017894:001, Table 11 Mandatory indicators, GWP-total row, A1-A3 column

A1–A3 covers raw-material supply, transport to manufacture and manufacturing. It is product-stage information, not a whole-life result.

Environmental Product Declaration

EPD recorded
Coverage
Product family
Declared unit
1 m² of CIMENTO® WILL cladding slab, excluding packaging (5 kg/m² at 2.5 mm; 11.3 kg/m² at 8 mm)
Programme
EPD International AB — The International EPD System
Registration
EPD-IES-0017894:001
Standard
EN 15804+A2
Valid until
2030-03-17
Verification
Third-party verified
Read the EPDSource: EPD-IES-0017894:001, Table 11 Mandatory indicators, GWP-total row, A1-A3 column

Carbon profile

kgCO2e per 1 m² of CIMENTO® WILL cladding slab, excluding packaging (5 kg/m² at 2.5 mm; 11.3 kg/m² at 8 mm) · each bar starts at zero · local scale

A1-A3 product

16.5

A4-A5 site*

5.94

B use

not declared

C end of life

16.5

D reuse / recycling

not declared

End of life is the largest of the modules this EPD declares.

adds carbon stores or removes EPD scenario* reuse/recycling potential (D)
* EPD transport and installation scenario, not this project's. Not declared: use, reuse / recycling. Do not compare bar lengths between materials. Each chart may use a different scale and declared unit.

Reported GWP Modules

Displayed as stored; modules are not added together here.

A1–A3

16.5 kgCO₂e

per 1 m² of CIMENTO® WILL cladding slab, excluding packaging (5 kg/m² at 2.5 mm; 11.3 kg/m² at 8 mm)

A4*

0.0114 kgCO₂e

per 1 m² of CIMENTO® WILL cladding slab, excluding packaging (5 kg/m² at 2.5 mm; 11.3 kg/m² at 8 mm)

A5*

5.93 kgCO₂e

per 1 m² of CIMENTO® WILL cladding slab, excluding packaging (5 kg/m² at 2.5 mm; 11.3 kg/m² at 8 mm)

C1

0.0578 kgCO₂e

per 1 m² of CIMENTO® WILL cladding slab, excluding packaging (5 kg/m² at 2.5 mm; 11.3 kg/m² at 8 mm)

C2

0.22 kgCO₂e

per 1 m² of CIMENTO® WILL cladding slab, excluding packaging (5 kg/m² at 2.5 mm; 11.3 kg/m² at 8 mm)

C3

0.0669 kgCO₂e

per 1 m² of CIMENTO® WILL cladding slab, excluding packaging (5 kg/m² at 2.5 mm; 11.3 kg/m² at 8 mm)

C4

16.2 kgCO₂e

per 1 m² of CIMENTO® WILL cladding slab, excluding packaging (5 kg/m² at 2.5 mm; 11.3 kg/m² at 8 mm)

* A4/A5 are EPD scenarios, not project-specific results. Module nomenclature follows BS EN 15978 / EN 15804. Declared values are suitable as inputs to a whole life carbon assessment under the RICS Professional Standard (2nd edition); this panel is not an assessment.

Upfront Carbon (A1–A5)*

22.4 kgCO₂e per 1 m² of CIMENTO® WILL cladding slab, excluding packaging (5 kg/m² at 2.5 mm; 11.3 kg/m² at 8 mm)

A1–A3 16.5 + A4 0.0114 + A5 5.93 · GWP-total, as declared

* Includes the EPD’s A4/A5 scenario assumptions, not project-specific transport or installation. This is the aggregation the proposed Part Z applies upfront limits to. The A1–A3 figure includes declared biogenic storage of 0.66 kgCO₂e; Part Z aggregates upfront carbon excluding sequestered carbon, which is the assessor's adjustment to make.

Sourced Product Claims

  • Third-party verified EPD (EPD-IES-0017894:001)Third-party verifiedSource
  • Declaration is held by SAI Industry S.r.l., not by the UK distributorThird-party verifiedSource
  • The declaration forbids quoting A1–A3 without module CThird-party verifiedSource

Evidence Sources

CIMENTO WILL Environmental Product Declaration

EPD International AB — The International EPD System · EPD-IES-0017894:001, Table 11 Mandatory indicators, GWP-total row, A1-A3 column

Coverage: 1 m² of CIMENTO® WILL cladding slab, excluding packaging (5 kg/m² at 2.5 mm; 11.3 kg/m² at 8 mm)

Third-party verified

Comparison Status

This result should be displayed for information only and not ranked against another product.

  • • The PCR and version are missing.

Design & Specification Notes

Qualitative notes for early design discussion. Not product-specific EPD evidence, and not a basis for numerical comparison.

Cast concrete cladding slab in sandblasted, smooth and Rio Terà finishes, declared per square metre.

Typical Uses

  • Primary flooring
  • High-traffic circulation
  • Work areas

Key Performance

Hard-wearing surface for high footfall.

Typical Service-Life Estimate

25 years

Generic estimate for early design discussion; confirm with the manufacturer.

Specification Actions

  • Confirm the current EPD covers the selected product, finish and manufacturing route.
  • Calculate transport distances for primary materials.
  • Document material reuse or reclaimed content percentages.

Indicative Health & Indoor Air

low Risk
Evidence:Third-party verified

Specification

Range
WILL
Finish
Cast concrete cladding slab — sandblasted, smooth or Rio Terà