BauderTHERMOFOL U FR

Bauder’s fire-retardant PVC single ply roofing membrane on a synthetic polyester reinforcement, for mechanically fastened, adhered or ballasted flat roofs. UK thicknesses 1.2, 1.5 and 1.8 mm in Light Grey, Anthracite and Blue Grey.

Manufacturer page
Bauder BauderTHERMOFOL U FR

Carbon and evidence

Product Evidence

Evidence currently held for the Bauder product record.

Bauder

Recorded Carbon Result

5.08kgCO₂e/m²

A1–A3 GWP-total per m² of average THERMOFOL PVC-P membrane (2.01 kg/m²), per IBU EPD-BAU-20220193-IBC1-DE; product variance −24% / +55%

Indicator: GWP-total

A1–A3 covers raw-material supply, transport to manufacture and manufacturing. It is product-stage information, not a whole-life result.

Environmental Product Declaration

EPD recorded
Coverage
Product family
Declared unit
1 m² PVC-P roof membrane (average product, 2.01 kg/m²)
Programme
Institut Bauen und Umwelt e.V. (IBU)
Registration
EPD-BAU-20220193-IBC1-DE
Standard
EN 15804+A2
Valid until
2027-10-19
Verification
Third-party verified

German-language IBU product EPD declaring BauderTHERMOFOL U (12/15/18/20/24) and M as a production-weighted average; stated GWP-total variance −24% / +55% by product. Bauder’s own NBS Source listing attaches this declaration to the UK U FR grade.

Reported GWP Modules

Displayed as stored; modules are not added together here.

A1–A3

5.08 kgCO₂e

per 1 m² average PVC-P membrane (2.01 kg/m²)

* A4/A5 are EPD scenarios, not project-specific results. Module nomenclature follows BS EN 15978 / EN 15804. Declared values are suitable as inputs to a whole life carbon assessment under the RICS Professional Standard (2nd edition); this panel is not an assessment.

Service Life — the B4 Replacement Input

35 years · manufacturer declared

≈2 installations over a 60-year building study period.

B4 (replacement) follows the building, not the product: an assessor multiplies replacement cycles by project quantities. This record supplies the service life and does not compute B4.

Comparison Status

This result should be displayed for information only and not ranked against another product.

  • • The PCR and version are missing.
  • • The carbon result is not linked to an evidence source.
  • • The EPD is not linked to an evidence source.

Evidence Gaps

  • No A4–D lifecycle results are held beyond the product stage.
  • No product-specific circularity or material-health claims are recorded.

Design & Specification Notes

Qualitative notes for early design discussion. Not product-specific EPD evidence, and not a basis for numerical comparison.

Bauder’s fire-retardant PVC single ply roofing membrane on a synthetic polyester reinforcement, for mechanically fastened, adhered or ballasted flat roofs.

Typical Uses

  • Roof coverings
  • Waterproofing layer
  • Weather protection

Key Performance

High durability in wet exposure and wind uplift.

Specification Actions

  • Confirm the current EPD covers the selected product, finish and manufacturing route.
  • Calculate transport distances for primary materials.
  • Document material reuse or reclaimed content percentages.

Indicative Health & Indoor Air

low Risk

Installation risks (torch application, hot-air welding) are the installer’s to manage; follow the current Bauder guidance.

Evidence:Third-party verified

Specification

Finish
PVC-P single ply membrane, polyester reinforced, FR grade
Thickness
1.2 / 1.5 / 1.8 mm
Service life
35 years

Cookies — essential ones keep the site working; optional analytics help us improve it. No advertising cookies.