Accoya Cladding

Cladding of Accoya® — radiata pine modified by acetylation, giving Class 1 durability (≈50 years above ground) and very high dimensional stability without biocides. Takes coatings well or weathers to silver-grey. A long-life timber cladding from FSC-certified fast-grown pine.

Manufacturer page
Accoya Accoya Cladding

Carbon and evidence

Product Evidence

Evidence currently held for the Accoya product record.

Accoya

Recorded Carbon Result

2.24kgCO₂e/m²

A1–A3 GWP-total per m² of cladding, per EPD (acetylation offsets biogenic storage)

A1–A3 covers raw-material supply, transport to manufacture and manufacturing. It is product-stage information, not a whole-life result.

Environmental Product Declaration

EPD recorded
Coverage
Representative product
Declared unit
1 m² cladding (15 mm planks + spruce framing + fasteners)
Programme
Self-published EPD (LCA by Agrodome B.V.)
Registration
Not recorded
Standard
EN 15804+A2 (ISO 14025 Type III)
Valid until
2027-02-18
Verification
Manufacturer declared

ISO 14025 Type III EPD; the document states independent third-party verification, but carries no programme registration number (self-published via Agrodome). A1–A3 is low-positive, not negative like raw timber: acetylation (fossil A1 = 11.8) roughly cancels the biogenic storage (−9.98). Long service life is the trade-off.

Carbon profile

kgCO2e per 1 m² cladding · each bar starts at zero · local scale

A1-A3 product

2.24

A4-A5 site*

-1.29

B use

not declared

C end of life

10.5

D reuse / recycling

-0.744

End of life is the largest of the modules this EPD declares.

adds carbon stores or removes EPD scenario* reuse/recycling potential (D)
* EPD transport and installation scenario, not this project's. Not declared: use. Module D shows potential impacts or benefits from reuse, recovery or recycling after the product's assessed life. It is reported separately and never added to A-C. Do not compare bar lengths between materials. Each chart may use a different scale and declared unit.

Reported GWP Modules

Displayed as stored; modules are not added together here.

A1–A3

2.24 kgCO₂e

per 1 m² cladding

A4*

0.387 kgCO₂e

per 1 m² cladding

A5*

-1.68 kgCO₂e

per 1 m² cladding

C1

0 kgCO₂e

per 1 m² cladding

C2

0.15 kgCO₂e

per 1 m² cladding

C3

7.85 kgCO₂e

per 1 m² cladding

C4

2.47 kgCO₂e

per 1 m² cladding

D

-0.744 kgCO₂e

per 1 m² cladding

* A4/A5 are EPD scenarios, not project-specific results. Module D is outside the A–C system boundary and is not added to A–C. Module nomenclature follows BS EN 15978 / EN 15804. Declared values are suitable as inputs to a whole life carbon assessment under the RICS Professional Standard (2nd edition); this panel is not an assessment.

Upfront Carbon (A1–A5)*

0.947 kgCO₂e per 1 m² cladding

A1–A3 2.24 + A4 0.387 + A5 -1.68 · as declared

* Includes the EPD’s A4/A5 scenario assumptions, not project-specific transport or installation. This is the aggregation the proposed Part Z applies upfront limits to.

Service Life — the B4 Replacement Input

60 years · EPD reference service life

The declaration's reference service life is 60 years, attributed to the manufacturer and conditional on the recommended maintenance schedule. Accoya warrant the cladding for up to 50 years, which is where this record's previous figure came from.

≈1 installation over a 60-year building study period.

B4 (replacement) follows the building, not the product: an assessor multiplies replacement cycles by project quantities. This record supplies the service life and does not compute B4.

3 claims and 2 certifications are held in the staging record but not presented as product evidence because an exact public source has not yet been mapped.

Comparison Status

This result should be displayed for information only and not ranked against another product.

  • • The PCR and version are missing.
  • • The GWP indicator is missing.
  • • The carbon result is not linked to an evidence source.
  • • The EPD is not linked to an evidence source.

Evidence Gaps

  • EPD registration number is missing.
  • 3 sustainability claims are withheld because exact public evidence is not mapped.
  • 2 certifications are withheld because exact public evidence is not mapped.

Design & Specification Notes

Qualitative notes for early design discussion. Not product-specific EPD evidence, and not a basis for numerical comparison.

Cladding of Accoya® — radiata pine modified by acetylation, giving Class 1 durability (≈50 years above ground) and very high dimensional stability without biocides.

Typical Uses

  • Facade cladding
  • Weather protection
  • External accents

Key Performance

Weather-resistant finish for facade exposure.

Specification Actions

  • Confirm FSC or PEFC certification for all timber products.
  • Request chain-of-custody documentation from supplier.
  • Confirm the current EPD covers the selected product, finish and manufacturing route.

Indicative Health & Indoor Air

low Risk

Acetylated timber (acetic-acid odour when freshly cut, dissipates); no biocides. Standard cutting-dust precautions.

Evidence:Published source

Specification

Range
Accoya wood cladding
Collection
Accoya Cladding
Finish
Acetylated modified-timber cladding
Service life
60 years

Cookies — essential ones keep the site working; optional analytics help us improve it. No advertising cookies.